2025-09-01 What are the letter codes fo···
Cross-linked polyethylene insulation YJMetal-plastic composite sheath ACopper conductor T PVC outer sheath 02Aluminum conductor L PE sheath 03Aluminum sheath Q Longitudinal water-blocking structure ZCorrugated aluminum sheath LWNote: Corrugated aluminum sheathing includes extruded corrugated aluminu
read more > -
2025-09-01 How many categories are ther···
Wire and cable products are divided into five categories: bare wire, wire and cable for electrical equipment, power cable, communication cable and optical cable, and winding wire.
read more > -
2025-09-01 What are the advantages of B···
What are the advantages of BTLY cables?1. BTLY series mineral insulated cables are available in sizes from 1.5 to 6 mm², with 3 to 61 cores; sizes from 95 to 240 mm², with 1 to 5 cores; and sizes from 240 to 630 mm², with single cores. Lengths can be customized to meet customer needs, and they ca
read more > -
2025-09-01 What types of commonly used ···
According to their uses, they can be divided into bare wires, insulated wires, heat-resistant wires, shielded wires, power cables, control cables, communication cables, radio frequency cables, etc.
read more > -
2025-09-01 What are the commonly used i···
Common insulated wires include: PVC insulated wire, PVC insulated soft wire, nitrile PVC mixture insulated soft wire, rubber insulated wire, agricultural underground direct buried aluminum core plastic insulated wire, rubber insulated cotton yarn textile soft wire, PVC insulated nylon sheathed wire,
read more > -
2025-09-01 What is the product structur···
BTLV and BTLY Aluminum-Sheathed Continuously Extruded Mineral Insulated CablesProduct Structure: 1. Conductor: Round Stranded Copper Wire (Softer Than the Solid Copper Rod of BTT)2. Insulation: Pure Gold Mica Tape (No Longer Composited with the Extruded Insulation, Eliminating Carbon Particles and I
read more > -
2025-09-01 What are the uses of NG-A (B···
NG-A (BTLY) flexible fireproof cable can be used in emergency after installation. It can also be used as a 125℃ halogen-free flame-retardant cable or fire-resistant cable. Because this series of cables has a wide coverage, it not only overcomes the defects of rigid fireproof cables, but also plays
read more > -
2025-09-01 What are the characteristics···
What are the characteristics of the NG-A (BTLY) flexible fire-resistant cable?① It meets the three fire resistance tests of BS6387: no breakdown under 950°C flame for 3 hours, no damage after 30 minutes at 650°C, and no damage after 15 minutes of water spray (direct immersion is also acceptable).
read more > -
2025-09-01 What are the main functions ···
The NG-A (BTLY) cable model uses aluminum as its primary material. Extruded metal tubes replace drawn copper tubes, simplifying the process and improving efficiency while significantly reducing product costs (aluminum costs only 1/10 of copper). The reason aluminum tubes can replace copper tubes is
read more > -
2025-09-01 NG-A (BTLY) product example
NG-A (BTLY) Product ExampleFor example:Insulated (flexible) mineral insulated cable, rated voltage 0.6/1kV, 4-core, nominal cross-section 120mm², represented as:NG-A (BTLY) 0.6/1kV 4×120Insulated (flexible) mineral insulated cable, rated voltage 0.6/1kV, 1-core, nominal cross-section 240mm², repr
read more >